specification ts-200-112 ts-200 -124 ts-200 -148 ts-200 -212 ts-200 -224 ts-200 -248 10a 0.63a 21 ~ 30vdc 87.5% 5a 0.32a 42 ~ 60vdc 88% 10a 0.63a 21 ~ 30vdc 87.5% 5a 0.62a 42 ~ 60vdc 88% model maximum output power waveform output frequency ac regulation typ. voltage range (typ.) efficiency (typ.) note.1 dc current (typ.) input input battery output environment fuse safety & emc bat. low alarm bat. low shutdown over temperature output short bat. polarity gfci proctection protection protection true sine wave (thd<3%) at rated input voltage 20a 1.25a 10.5 ~ 15vdc 86% 30a*2 30a*1 15a*1 15a*1 30a*1 3.0%, at rated input voltage 10.5 ~ 15vdc 86% 20a 1.25a 30a*2 85 5 protection type : shut down o/p voltage, re-power on to recover ; by internal rth1 detect power transistor protection type : shut down o/p voltage, re-power on to recover by internal fuse open optional (only type f) none -10 ~ +40 @ 100% load, +60 50% load emi conduction&radiation ems immunity compliance to fcc class a none working temp. remote control working humidity storage temp., humidity safety standards -10 ~ +35 @ 100% load ; +60 @ 50% load open : normal work ; short : remote off 20% ~ 90% rh non-condensing -30 ~ +70 / -22 ~ +158 f, 10 ~ 95% rh o design refer to ul458 none compliance to en61000-4-2,3,8 env50204 compliance to en55022 class a, 72/ 245/ cee, 95/ 54/ ce, e-mark true sine wave output (thd<3%) front panel indicator for operation status power on-off switch protections: bat. low alarm / bat. low shutdown / over voltage / over temp. / output short / input reverse polarity / overload application : home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. 2 years warranty high surge power up to 400w high efficiency up to 88% fanless design, cooling by free air convention built-in remote on-off control rated power 200w over load (typ.) 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. protection type : shut down o/p voltage, re-power on to recover withstand voltage isolation resistance bat. i/p - ac o/p:3.0kvac ac o/p - fg:1.5kvac bat. i/p-ac o/p, ac o/p-fg:100m ohms / 500vdc / 25 / 70% rh vibration 10 ~ 500hz, 3g 10min./1cycle, 60min. each along x, y, z axes features : others packing 1.63kg; 6pcs/10.8kg/1.44cuft dimension 205*158*59mm (l*w*h) note 1.efficiency is tested by 200w, linear load at 12v/24v/48v input voltage. 2.all parameters not specified above are measured at rated load, 25 of ambient temperature. 230w for 180 sec. / 300w for 10 sec. / surge power 400w for 30 cycles(typ.) 11.3 4 % 22.5 4 % 45 4 % 45 4 % 22.5 4 % 10.5 4 % 21 4 % 42 4 % 42 4 % 21 4 % 11.3 4% 10.5 4 % t s - 2 0 0 s e r i e s file name:ts-200-spec 2009-07-22 50 0.1hz 50/60hz selectable by setting button 60 0.1hz 50/60hz selectable by setting button front panel indicator operation status ; green : normal, orange(flashing) : remote control of f, red : abnormal 24v 48v 24v 48v bat. voltage 12v 12v no load current draw typ. off mode draw current 1ma battery types open & sealed lead acid 200w true sine wave dc-ac power inverter lvd none en60950-1 80 5 80 5 80 5 80 5 85 5 ac voltage 100 / 110 / 115 / 120vac selectable by setting button s.w factory setting set at 110vac 200 / 220 / 230 / 240vac selectable by setting button s.w factory setting set at 230vac e 13 function
mechanical specification type-a type-b load (%) environment temperature ( ) -10 10 20 30 40 35 50 60 70 (horizontal) 20 40 50 60 80 100 derating curve ts-200-2xx ts-200-1xx unit:mm file name:ts-200-spec 2009-07-22 t s - 2 0 0 s e r i e s true sine wave inverter 12:12vdc 24:24vdc bat. voltage: 48:48vdc 1:110vac 2:230vac output: o/p wattage:200w ts 200 112 a 200w true sine wave dc-ac power inverter a :type b :type c :type d :type e :type f :type ab c d e f outlet outlet outlet outlet outlet outlet _ status setting ac output ac output 24.82 10.7 59 status on off chassis ground reverse polarity will damage the unit. r.c setting 147 158 9 7 11 18 12 42.5 120 205 8.9 _ _ type-a receptacle type country certificate type-b type-c type-d type-e type-f usa europe australia u.k japan gfci ac output receptacles (optional) e e e 13 13 13 0
|