  Datasheet File OCR Text:
  specification ts-200-112 ts-200 -124 ts-200 -148 ts-200 -212 ts-200 -224 ts-200 -248 10a 0.63a 21 ~ 30vdc 87.5% 5a 0.32a 42 ~ 60vdc 88% 10a 0.63a 21 ~ 30vdc 87.5% 5a 0.62a 42 ~ 60vdc 88% model maximum output power waveform output frequency ac regulation typ. voltage range (typ.) efficiency (typ.) note.1 dc current (typ.) input input battery output environment fuse safety & emc bat. low alarm bat. low shutdown over temperature output short bat. polarity gfci proctection protection protection true sine wave (thd<3%) at rated input voltage 20a 1.25a 10.5 ~ 15vdc 86% 30a*2 30a*1 15a*1 15a*1 30a*1 3.0%, at rated input voltage 10.5 ~ 15vdc 86% 20a 1.25a 30a*2 85 5 protection type : shut down o/p voltage, re-power on to recover ; by internal rth1 detect power transistor protection type : shut down o/p voltage, re-power on to recover by internal fuse open optional (only type f) none -10 ~ +40 @ 100% load, +60 50% load emi conduction&radiation ems immunity compliance to fcc class a none working temp. remote control working humidity storage temp., humidity safety standards -10 ~ +35 @ 100% load ; +60 @ 50% load open : normal work ; short : remote off 20% ~ 90% rh non-condensing -30 ~ +70 / -22 ~ +158 f, 10 ~ 95% rh o design refer to ul458 none compliance to en61000-4-2,3,8 env50204 compliance to en55022 class a, 72/ 245/ cee, 95/ 54/ ce, e-mark true sine wave output (thd<3%) front panel indicator for operation status power on-off switch protections: bat. low alarm / bat. low shutdown / over voltage / over temp. / output short / input reverse polarity / overload application : home appliance, power tools, office and portable equipment, vehicle and yacht ...etc. 2 years warranty high surge power up to 400w high efficiency up to 88% fanless design, cooling by free air convention built-in remote on-off control rated power 200w over load (typ.) 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. protection type : shut down o/p voltage, re-power on to recover withstand voltage isolation resistance bat. i/p - ac o/p:3.0kvac ac o/p - fg:1.5kvac bat. i/p-ac o/p, ac o/p-fg:100m ohms / 500vdc / 25 / 70% rh vibration 10 ~ 500hz, 3g 10min./1cycle, 60min. each along x, y, z axes features : others packing 1.63kg; 6pcs/10.8kg/1.44cuft dimension 205*158*59mm (l*w*h) note 1.efficiency is tested by 200w, linear load at 12v/24v/48v input voltage. 2.all parameters not specified above are measured at rated load, 25 of ambient temperature. 230w for 180 sec. / 300w for 10 sec. / surge power 400w for 30 cycles(typ.) 11.3 4 % 22.5 4 % 45 4 % 45 4 % 22.5 4 % 10.5 4 % 21 4 % 42 4 % 42 4 % 21 4 % 11.3 4% 10.5 4 % t s - 2 0 0 s e r i e s file name:ts-200-spec 2009-07-22 50 0.1hz 50/60hz selectable by setting button 60 0.1hz 50/60hz selectable by setting button front panel indicator operation status ; green : normal, orange(flashing) : remote control of f, red : abnormal 24v 48v 24v 48v bat. voltage 12v 12v no load current draw typ. off mode draw current 1ma battery types open & sealed lead acid 200w true sine wave dc-ac power inverter lvd none en60950-1 80 5 80 5 80 5 80 5 85 5 ac voltage 100 / 110 / 115 / 120vac selectable by setting button s.w factory setting set at 110vac 200 / 220 / 230 / 240vac selectable by setting button s.w factory setting set at 230vac e 13 function
mechanical specification type-a type-b load (%) environment temperature ( ) -10 10 20 30 40 35 50 60 70 (horizontal) 20 40 50 60 80 100 derating curve ts-200-2xx ts-200-1xx unit:mm file name:ts-200-spec 2009-07-22 t s - 2 0 0 s e r i e s true sine wave inverter 12:12vdc 24:24vdc bat. voltage: 48:48vdc 1:110vac 2:230vac output: o/p wattage:200w ts 200 112 a 200w true sine wave dc-ac power inverter a :type b :type c :type d :type e :type f :type ab c d e f outlet outlet outlet outlet outlet outlet _ status setting ac output ac output 24.82 10.7 59 status on off chassis ground reverse polarity will damage the unit. r.c setting 147 158 9 7 11 18 12 42.5 120 205 8.9 _ _ type-a receptacle type country certificate type-b type-c type-d type-e type-f usa europe australia u.k japan gfci ac output receptacles (optional) e e e 13 13 13 0


▲Up To Search▲   

 
Price & Availability of TS-200-248

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X